Take Control of Welding Power Sources
The PurgeNet™ Machine Interface Lead is used for communicating the current oxygen reading from your PurgEye® Weld Purge Monitor® to another piece of equipment, such as a Welding Power Source.
All of the HFT® PurgEye® Weld Purge Monitors® reading down to 10 ppm (with the exception of the PurgEye® Nano) can control the start/stop function on a Welding Power Source. This is facilitated using the PurgeNet™ Machine Interface Lead.
For critical welds this is an essential feature to ensure consistent weld quality every time.
Contact us - See our Worldwide Offices
Read MoreGiving You Full Control of PPM Readings to your Power Source
PurgeNet™ Machine Interface allows a minimum PPM level to be set on the Weld Purge Monitor® by the user, in accordance with the welding parameter.
If during the weld, the oxygen content in the purge gas falls to this, the welding power source automatically switches off, pausing the welding process until the PPM level has risen again.
For critical welds this is an essential feature to ensure consistent weld quality every time.
The lead connects to the port on the Weld Purge® Monitor®, with a connection for an optional PurgeAlarm™ Visual Alarm Indicator™. Charging for the Weld Purge Monitor® can also be facilitated from the lead.
Oxygen readings are communicated through industry standard 4020A current loop and relay signals.
The interface also includes a power supply to charge / power your PurgEye® from a standard 12-24V supply found in most industrial machines.
Contact us - See our Worldwide Offices
Read MoreCommunicate with all your Machines
Using the PurgeNet™ Machine Interface Lead gives welders full control of their welding power sources or other equipment like no other
Communicate easily with the current oxygen reading from your PurgEye® Weld Purge Monitor® to another piece of equipment, such as a Welding Power Source.
A critical and essential feature to ensure weld consistency.
The lead connects to the port on the Weld Purge® Monitor®, with a connection for an optional PurgeAlarm™ Visual Alarm Indicator™.
Charging for the Weld Purge Monitor® can also be facilitated from the lead.
Optional items:
- PurgeNet™ Smart Cable.
- PurgeNet™ Visual Alarm Indicator™.
- PurgeLog™ Data Logging Software. PurgeNet™ Smart Cable also works
with software PurgeLog™ to easily transfer weld purge data for
Quality Control purposes.
Contact us - See our Worldwide Offices
Read MoreTechnical Data and Specification
The PurgeNet™ Machine Interface Lead connects to the port on the Weld Purge Monitor®. Charging can also be facilitated from this lead as can the use of other PurgeNet™ accessories.
Oxygen readings are communicated through industry standard 4020A current loop and relay signals. The interface also includes a power supply to charge / power your PurgEye® Weld Purge Monitors from a standard 12-24V supply found in most industrial machines.
OUTPUT
For PurgEye® Weld Purge Monitors® with 10 to 1000 ppm range, the current output from the interface is linear, with 4mA representing 0 ppm and 20mA representing 1,000 ppm, with a resolution better than 1 ppm.
For the PurgEye® 600 Touch, with a measuring range of 10 to 250, 000 ppm, the current output is split into two linear output ranges, as follow:
PurgEye® 600 Touch
0 – 1,000 ppm
1,000 – 250,000 ppm
Current Output
4mA - 12mA
12mA - 20mA
Resolution
< 1 ppm
~ 100 ppm
STATUS LIGHT
Slow flash
PNA-01 is correctly powered and receiving valid data from your PurgEye®.
On
PNA-01 is correctly powered but no data is being received from your PurgEye®.
Off
The PNA-01 is not powered, ensure the current loop and supply connections are correctly configured. See ‘Connections’ below.
CONNECTIONS
The basic connections required to get the module working are shown below (the power supply is optional for battery powered models). The status input can be used to control the sample pump in your PurgEye®, use a volt-free contact to connect the ‘IN’ terminal to the ‘0 VDC’ terminal to activate the input.
PurgEye® Weld Purge Monitors®
LIN (PurgeNet™ Data)
NEG (PurgeNet™ Ground)
POS (PurgeNet™ Supply)
IN (Status)
0 VDC
+12 - 24 VDC
12-24 V
Power supply
For voltage output using the 4-20mA output, connect as below:
Relay 1
Relay 1
Relay 2
Relay 2
4 - 20mA
4 - 20mA
12-24 V
Power supply
100 ohm Resistor
The 10 ppm Weld Purge Monitors (excluding the Nano) PurgEye® 200, PurgEye® 500, PurgEye® 600, PurgEye® 1000 and PurgEye® 1500 Site all now comes complete with PurgeNet™ Smart Cable.
Please see individual PurgEye® Weld Purge Monitors® for further specification.
Auxiliary items:
- PurgeNet™ Smart Cable for charging with multi-plug options
- PurgeAlarm™ Traffic Light Visual warning accessory
- PurgeLog™ Data Logging Software for Quality Control
Compare all Weld Purge Monitors
Contact us - See our Worldwide Offices
Read MoreFrequently Asked Questions
1.0 What is the PurgeNet™ Machine Interface?
PurgeNet™ Machine interface is used for communicating the current oxygen readings from your PurgEye® Weld Purge Monitor® to another piece of equipment, such as a Welding Power Source.
2.0 Which Weld Purge Monitors® are compatible with the PurgeNet™ Machine Interface?
The PurgeNet™ Machine Interface is compatible with the PurgEye® 200, 500 Desk, 600, 1000 Remote and 1500 Site.
3.0 How does the PurgeNet™ Machine Interface connect?
Essentially, the PurgeNet™ Machine Interface is a lead that connects to the port on the Weld Purge Monitor®. Charging can also be facilitated from this lead as can the use of other PurgeNet™ accessories.
4.0 How are oxygen readings communicated?
A minimum PPM level is set on the Weld Purge Monitor® by the user, in accordance with the welding parameter, and if during the weld, the oxygen content in the purge gas falls to this, the welding power source automatically switches off, pausing the welding process until the PPM level has risen again. Oxygen readings are communicated through industry standard 4020A current loop and relay signals.
Contact us - See our Worldwide Offices
Read MoreShipping Information, Weights and Dimensions
Customs Tariff
European Customs Tariff: | 9026 1089 |
International Customs Tariff: | 9026 80 6000 |
United States Customs Tariff: | 9026 80 6000 |
Canada Customs Tariff: | 9026 80 6000 |
Product Codes and Sizes
Shipping Dimensions | To Follow Shortly - mm |
Nett weight | 0.2 kg |
Volumetric weight with case | 0.3 kg |
The PurgEye® Auxiliaries for the Argweld® Family Range of PurgEye® Weld Purge Monitors® (10 ppm - excluding Nano) are held in stock and available for immediate delivery.
PART Nº | PRODUCT DESCRIPTION |
DPS1000 PNA-01 PNA-02 PNA-021 PNA-022 ATMS002 PNA-05 |
PurgeNet™ Dew Point Purging Gas Moisture Sensor™ PurgeNet™ Weld Machine Interface (for PPM Readings to Welding Power Sources, such as Orbital Welder) PurgeAlarm™ Visual Alarm Indicator, red light only PurgeAlarm™ Visual Alarm Indicator, green light (fitted on top of red light) Bracket for PurgeAlarm™ PurgeLog™ Data Logging Software for Quality Control PurgeNet™ Smart Cable with multi-plug options, charging, alarms, software |
PurgeAlarm™ (NOTE: for use with PurgeNet™)
Contact us - See our Worldwide Offices
Read MoreItems available as 'Downloads'
Leaflets and general sales material are available to everyone visiting our website.
Restricted access items are shown at the end of this Download section.
PurgeNet™ Automatic Machine Interface A4 Leaflet
PurgeNet™ Automatic Machine Interface Information Flyer
PurgeNet™ Automatic Machine Interface Information FAQ
PurgeNet™ Dew Point Purging Gas Moisture Sensor™ A4 Leaflet
PurgeNet™ Dew Point Purging Gas Moisture Sensor™ Information Flyer
PurgeNet™ Dew Point Purging Gas Moisture Sensor™ FAQ
PurgeNet™ Smart Cable A4 Leaflet
PurgeNet™ Smart Cable Information Flyer
PurgeNet™ Smart Cable FAQ
PurgeAlarm™ Visual Alarm Indicator A4 Leaflet
PurgeAlarm™ Visual Alarm Indicator Information Flyer
PurgeAlarm™ Visual Alarm Indicator Information FAQ
PurgeLog™ Data Logging Software Information Flyer
PurgeLog™ Data Logging Software FAQ
Argweld® PurgEye® Weld Purge Monitors® Filters
Return on Investment (ROI) Weld Purge Monitors and Weld Purging Systems
Understanding Atmosphere in PPM
Parts Per Million vs Percentage of Oxygen
Argweld® PurgEye® Weld Purge Monitors® Poster
Argweld® PurgEye® Weld Purge Monitors® Technical Tips Training Posters
Argweld® PurgEye® Weld Purge Monitors® Family Range Information Flyer
Technical Comparison Table of all Argweld® PurgEye® Weld Purge Monitors®
Special Note: The items below are restricted and only available in our Secure Login section. This is mainly for the protection of our Exclusive Distributor network.
Should you wish to receive an item mentioned below which is not active as a 'download' link on this page, please contact us or your nearest Distributor.
PurgeNet™ Machine Interface User Instructions Technical Manual
PurgeNet™ Machine InterfaceTechnical Notes
PurgeNet™ Machine Interface User List Customer Service
PurgeNet™ Machine Interface Price List
Contact us - See our Worldwide Offices
Read More