- Product
- Overview
- Key Features
- Ordering
- Downloads
- Gallery
Smart Control for your Purging
Our revolutionary PurgeNet™ Smart Cable can connect together smart accessories for weld purging, including the PurgeAlarm™ Traffic Light System which gives a visual warning during welding in case of rising of falling oxygen levels or for charging / power for your Weld Purge Monitor.
PurgeNet™ Smart Cable can also be used in conjunction with PurgeLog™ software to transfer weld purge data to a PC for quality control purposes.
Contact us - See our Worldwide Offices
Read MoreGiving You Full Control of your Welding Accessories
Our high spec Weld Purge Monitors® reading down to 1 ppm (accurate to 10 ppm) are shipped as standard with a PurgeNet™ Smart Cable, a lead connection and machine interface.P
The range included are the PurgEye® 200, PurgEye® Desk, PurgEye® 600, PurgEye® 1000 and PurgEye® 1500 Site.
PurgeNet™ Smart Cable can control charging, quality control software and visual alarms.
Optional items:
- PurgeNet™ Automatic Weld Machine Interface (for PPM Readings for your welding power sources.
- PurgeAlarm™ Traffic Light Visual Alarm warning accessory.
- PurgeNet™ also works with PurgeLog™ to easily transfer weld purge data for Quality Control purposes.
- Dew Point Purging Gas Moisture Sensor™
Contact us - See our Worldwide Offices
Read MoreSmart Features for your Weld Purge Monitor®
PurgeNet™ Smart Cable give welders full control of their welding accessories like no other, allowing any of our 1 ppm (accurate to 10 ppm) Weld Purge Monitors®.
The PurgeNet™ Smart Lead allows accessories to be connected.
These include:
- Charging and Power to your Weld Purge Monitor®
- An external audible and visual warning devices
- PurgeLog™ Data Logging Software Quality Control
PurgeNet™ Smart Lead with Machine Interface is simply connected to the Weld Purge Monitor®.
Our 1 ppm (accurate to 10 ppm) Weld Purge Monitors the PurgEye® 200, PurgEye® Desk, PurgEye® 600, PurgEye® 1000 and PurgEye® 1500 Site all now shipped 'as standard' with PurgeNet™ Smart Cable.
Contact us - See our Worldwide Offices
Read MoreShipping Information, Weights and Dimensions
Customs Tariff
European Customs Tariff: | 9026 1089 |
International Customs Tariff: | 9026 80 6000 |
United States Customs Tariff: | 9026 80 6000 |
Canada Customs Tariff: | 9026 80 6000 |
Product Codes and Sizes
Shipping Dimensions | To Follow Shortly - mm |
Nett weight | 0.3kg |
Volumetric weight with case | 0.4 kg |
The Argweld® PurgeNet™ Weld Machine Interface Lead for the Family range of PurgEye® Weld Purge Monitors® (10 ppm - excluding Nano) are held in stock and available for immediate delivery.
PNA-01 PNA-02 PNA-021 PNA-022 ATMS002 PNA-05 |
PurgeNet™ Weld Machine Interface (for PPM Readings to Welding Power Sources, such as Orbital Welder) PurgeAlarm™ Visual Alarm Indicator, red light only PurgeAlarm™ Visual Alarm Indicator, green light (fitted on top of red light) Bracket for PurgeAlarm™ PurgeLog™ Data Logging Software for Quality Control PurgeNet™ Smart Cable with multi-plug options, charging, alarms, software |
PurgeAlarm™ (NOTE: for use with PurgeNet™)
Contact us - See our Worldwide Offices
Read MoreItems available as 'Downloads'
Leaflets and general sales material are available to everyone visiting our website.
Restricted access items are shown at the end of this Download section.
PurgeNet™ Smart Cable A4 Leaflet
PurgeNet™ Smart Cable Information Flyer
PurgeNet™ Dew Point Purging Gas Moisture Sensor™ A4 Leaflet
PurgeNet™ Dew Point Purging Gas Moisture Sensor™ Information Flyer
PurgeAlarm™ Visual Alarm Indicator A4 Leaflet
PurgeAlarm™ Visual Alarm Indicator Information Flyer
PurgeAlarm™ Visual Alarm Indicator Information FAQ
PurgeNet™ Data Logging Software A4 Leaflet
PurgeNet™ Data Logging Software Information Flyer
PurgeNet™ Automatic Machine Interface A4 Leaflet
PurgeNet™ Automatic Machine Interface Information Flyer
PurgeNet™ Automatic Machine Interface Information FAQ
Argweld® PurgEye® Weld Purge Monitors® Filters
Return on Investment (ROI) Weld Purge Monitors and Weld Purging Systems
Understanding Atmosphere in PPM
Parts Per Million vs Percentage of Oxygen
Argweld® PurgEye® Weld Purge Monitors® Poster
Argweld® PurgEye® Weld Purge Monitors® Technical Tips Training Posters
Argweld® PurgEye® Weld Purge Monitors® Family Range Information Flyer
Technical Comparison Table of all Argweld® PurgEye® Weld Purge Monitors®
Special Note: The items below are restricted and only available in our Secure Login section. This is mainly for the protection of our Exclusive Distributor network.
Should you wish to receive an item mentioned below which is not active as a 'download' link on this page, please contact us or your nearest Distributor.
Argweld® PurgeNet® Smart Cable User Instructions Technical Manual
Argweld® PurgeNet® Smart CableTechnical Notes
Argweld® PurgeNet® Smart CableWeld Purge Monitor® User List Customer Service
Argweld® PurgeNet® Smart Cable Weld Purge Monitor® Price List
Contact us - See our Worldwide Offices
Read More